Pin 14 Yellow/Black - Engine sensing input. This wire is connected to the vehicles Tach or Alternator
wire and is required if you are not using the no tach sense setting. IMPORTANT: To change
engine-sensing modes, you must change Option 2-10; Default requires a Tach input.
Pin 15 White [POC 8]
- Horn honk 250mA negative (-) output. This is an optional output that will pulse
the factory horn. The proper wire will show ground (-) while the horn is sounding. To change horn
output settings, review Options 3-8 and 3-9.
Pin 16 Gray/Black
– Hood Pin negative (-) input. This input is a safety shut down and alarm trigger. It
prevents the vehicle from remote starting while the hood is open and triggers the alarm if the
hood is opened while the alarm is armed. You can connect this wire to the hood pin supplied with
this kit, or to a wire in the vehicle that shows (-) only while the hood is open.
Pin 17 Violet [POC 9]
- Dome light 250mA negative (-) output. This is an optional output that will provide
a 30 second (-) negative output after system is unlocked for dome-light supervision. To change
dome light output settings, review Option 3-2.
Pin 18 Brown
- Siren 12V positive (+) output. Connect this wire to the (+) wire located on the siren. To
change siren output settings, review Option 3-7.
Connector 4 (CN4), 6-Pin
Pin 1 Not used
Pin 2 Violet/White
- Trunk release 250mA negative (-) output. This is an optional output that will
release the trunk. Use CN1, Pin 2 if the vehicle is equipped with a (+) trunk release. System will
unlock doors and disarm alarm prior to trunk release.
Pin 3 Orange/Black
- 2
nd
Unlock 250mA negative (-) output. This is an optional output that will provide
a (-) pulse for driver’s priority door lock. IMPORTANT: You must isolate the driver’s door and
turn on Option 1-3.
Pin 4 Blue
- Unlock 250mA negative (-) output. This is an optional output that will provide a (-) pulse for
unlocking doors. System will unlock doors and disarm alarm. IMPORTANT: You must reverse
polarity for (+) trigger door lock systems. For additional lock settings review Option Group
1 (page 31).
Pin 5 Blue/Black
- Lock 250mA (-) negative output. This is an optional output that will provide a (-)
pulse for locking doors. System will lock doors and arm alarm. IMPORTANT: You must reverse
polarity for (+) trigger door lock systems. For additional lock settings review Option Group
1 (page 31).
Pin 6 Not used
Connector 5 (CN5), 2-Pin (Pre-wired LED)