CM5200 Wiring Schematic (Remote Start)
The CM5200 is the control module for all remote start units. This controller is universal regardless of
remote or antenna type.
( - ) Switch 3 Gray
1 Red
2 Green /
White
1: ( + ) 12v Constant 2: ( + ) Parking Light
( + ) Led 2 Gray
3 Red/White 4 White
3: ( + ) 12v Constant Red / White
prewired to 2
nd
Relay
4: ( + ) Accessory
( - ) Led 1 Gray/Black
CN9
Plug In
LED/Valet
Switch
5 Violet 6 Yellow
5: ( - ) When Armed prewired to
Anti-Grind Relay
6: ( + ) Starter prewired to
Anti-Grind Relay
CN1
7 Green and
Red
8 Black
7: ( + ) Ignition Red prewired to
Anti-Grind Relay
8: ( - ) Ground
LED ( + ) Black / White
LED ( - ) Black
CN5
LED
ADS Blade Connector
(20 Pin Harness)
Please see the installation manual
for the Blade module for details.
This harness is not
included with the CM5200.
1 Green / White 2 Lt Blue 1: ( - ) Parking Lt. Output – POC 1 2: ( - ) E-Brake Input
( - ) 4 Black
3 Red / Black
4 Lt. Blue /
White
3: ( - ) Starter Output – POC 2 4: ( + ) Brake Input
( + ) 3 White
5 Green 6 Violet / Black 5: ( - ) Ignition Output – POC 3 6: ( - ) Trunk Input
TX 2 Red
7 White / Black 8 Red / White 7: ( - ) Accessory Output – POC 4 8: ( - ) Door Input
RX 1 Yellow
CN8
Antenna
9 Black
10 Brown /
White
9: ( - ) Status Out (GWR) – POC 5
10: ( - ) Glow Input/Key
Sensing
11 Orange 12 Pink 11: ( - ) Rearm Output – POC 6
12: ( - ) Slave/Closed Loop
Input
13 Orange /
White
14 Yellow /
Black
13: ( - ) Disarm Output – POC 7
14: (AC) Tach / Alternator
Input
4 ( - )
15 White
16 Gray /
Black
15: ( - ) Horn Output – POC 8 16: ( - ) Hood Input
3 ( + )
CN3
17 Violet 18 Brown 17: ( - ) Dome Light – POC 9 18: ( + ) Siren Output
2 Data
1 Data
CN12
RS232
1 Black / White
CN11
Thermistor
2 Black
( + ) 12v
Constant Power None
( - ) Lock Output 5 Blue / Black
( - ) Unlock
Output 4 Blue
( - ) Second
Unlock Output
3 Orange /
Black
( - ) Trunk
release output
2 Violet /
White
Green/White Loop
Cut=Auto Trans. Uncut=Manual
Trans.
Every control module has this wire
intact and must be cut for automatic
Future use None
CN4
( + ) ( - )
Default
Door Trigger Polarity
( + ) ( - )
Default
Key Sense/Glow Plug Polarity
Jumpers
( + ) Parking
Lights
Trunk Release
Blade Cartridge Slot - Please visit
www.idatalink.com/compustar for
compatibility and more information. This
slot is empty and has a plastic cover that
slides off.
IMPORTANT: Manufacturer or seller will have